Novec 1230 Fire Suppression for battery room
Novec 1230 Fire Suppression for battery room
Novec 1230 Fire Suppression for battery room
Novec 1230 Fire Suppression for battery room
Novec 1230 Fire Suppression for battery room
Novec 1230 Fire Suppression for battery room
Novec 1230 Fire Suppression for battery room
Novec 1230 Fire Suppression for battery room
Novec 1230 Fire Suppression for battery room
Novec 1230 Fire Suppression for battery room
Novec 1230 Fire Suppression for battery room
Novec 1230 Fire Suppression for battery room

Novec 1230 Fire Suppression for battery room

Price 45000.0 INR/ Piece

MOQ : 1 Piece

Novec 1230 Fire Suppression for battery room Specification

  • Mounting Type
  • FLOOR/ WALL
  • Fire Class
  • A,B,C
  • Color
  • Red
  • Coating Type
  • CROME
  • Control Type
  • AUTOMATIC
  • Coverage Area
  • ENTIRE Square Meter (m2)
  • Shape
  • FIRE CYLINDER
  • Material
  • CCOE or PESO approved
  • Working Temperature
  • 100-120 Celsius (oC)
  • Product Type
  • Clean agent fire suppression
  • Features
  • AUTOMATIC
  • Frequency
  • 50 Hertz (HZ)
  • Alarm
  • yes
  • Dimension (L*W*H)
  • 1.5 x 1 x 1 Meter (m)
  • Usage
  • Industrial and commercial
  • Installation Type
  • CUSTOMIZE
  • Connectivity Type
  • STANDARD
  • Weight
  • 100 Kilograms (kg)
  • Input Power
  • 24 Volt (V)
  • Operating Pressure
  • 15/25 Bar
  • Energy Efficiency Rating
  • 5
  • Fire Extinguisher Type
  • AUTOMATIC FIRE PROTECTION
  • Warranty
  • 12 month
  • Voltage
  • 24/ 230 Volt (v)
  • Temperature Range
  • 100-120 Celsius (oC)
  • Technology
  • AUTOMATIC
  • Application
  • Battery room fire protection system
  • Max Flow Rate
  • as per VDS/ NFPA
  • Capacity
  • ANY Kg
  • Diameter
  • any Meter (m)
  • Pressure
  • 15/25 Bar
 

Novec 1230 Fire Suppression for battery room Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 200 Pieces Per Month
  • Delivery Time
  • 4 Week
  • Main Domestic Market
  • All India
  • Certifications
  • UL & CE
 

About Novec 1230 Fire Suppression for battery room

Novec 1230 Fire Suppression System for Battery Rooms Clean Agent Protection

The Novec 1230 Fire Suppression System for Battery Rooms is an advanced automatic fire protection solution designed to safeguard battery rooms, UPS battery banks, energy storage systems, and inverter battery areas from fire risks caused by overheating, short circuits, off-gassing, and thermal runaway.


This system uses Novec 1230 (FK-5-1-12) clean agent, which suppresses fire rapidly by absorbing heat and interrupting the combustion process. The agent is non-conductive, residue-free, and non-corrosive, making it safe for energized electrical and battery equipment while ensuring no damage and minimal downtime after discharge.


The Novec 1230 fire suppression system operates on the total flooding or localized protection principle, activated automatically through smoke detectors, heat detectors, or fire detection tube technology. It provides early-stage fire suppression, preventing fire spread and protecting critical power infrastructure.


Key Features

  • Automatic clean agent fire suppression

  • Designed for battery & energy storage fire risks

  • No residue, no corrosion, no equipment damage

  • Safe for live batteries & electrical systems

  • Fast response and high extinguishing efficiency

  • Environment friendly (zero ODP, very low GWP)

  • Low maintenance and high system reliability


Applications

  • Battery rooms & UPS battery banks

  • Data center battery rooms

  • Telecom battery rooms

  • Inverter & power backup rooms

  • Energy storage systems (ESS / BESS)


Compliance

  • Designed as per NFPA 2001 / ISO 14520

  • Suitable for electrical & battery fire protection


Keywords

Novec 1230 fire suppression for battery room, battery room fire suppression system, clean agent fire suppression for batteries, UPS battery room fire protection, FK-5-1-12 battery fire suppression system.



Comprehensive Battery Room Protection

Novec 1230 provides thorough fire suppression for battery rooms, addressing the unique hazards of high-capacity energy storage. Its capability to handle Class A, B, and C fires ensures fire safety for a range of scenarios. Automated controls and real-time alarm systems enable rapid action, minimizing downtime and preventing extensive damage to expensive electrical infrastructure.


Advanced Automatic Suppression Technology

Equipped with advanced automatic technology, the Novec 1230 system detects fires at their earliest stage. Its seamless integration with standard connectivity types and customizable installation options guarantees adaptability to different battery room layouts. Energy efficiency and precise operating pressure make it ideal for critical industrial applications.

FAQ's of Novec 1230 Fire Suppression for battery room:


Q: How does the Novec 1230 Fire Suppression System protect battery rooms?

A: The Novec 1230 system uses a specialized chemical agent to quickly suppress fires originating from electrical faults or battery malfunctions. Its automatic activation ensures that fires are detected and controlled before they can spread, minimizing risk and potential damage in battery storage areas.

Q: What types of fires can the Novec 1230 system extinguish in battery rooms?

A: This system is certified for Class A, B, and C fires, meaning it effectively handles combustibles, flammable liquids, and electrical fires-making it ideal for complex battery storage environments.

Q: When should the Novec 1230 system be installed in a battery room?

A: It is recommended to install the system during the initial construction or major retrofit of battery rooms. Doing so ensures seamless integration with electrical and safety infrastructure and maximizes fire protection coverage.

Q: Where can the Novec 1230 system be installed?

A: The system is suitable for both floor and wall mounting, with its compact fire cylinder shape allowing flexible installation in virtually any battery room configuration, tailored to your facility's spatial and operational requirements.

Q: What is the process for using the Novec 1230 system in case of fire?

A: Once the integrated sensors detect a fire, the system activates automatically, releasing Novec 1230 agent to suppress the fire rapidly. Manual intervention is typically not required, thanks to its automatic controls and alarm integration.

Q: What are the primary benefits of Novec 1230 in battery room fire protection?

A: Benefits include rapid fire suppression, minimal residue or equipment damage, high safety for electrical components, a 12-month warranty, and compliance with major safety standards and approvals. This ensures operational continuity and asset protection.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Server & Data center fire suppression system Category

Fire Detection and Suppression System

Fire Detection and Suppression System

Price 155000.0 INR / Piece

Minimum Order Quantity : 1 Set

Material : UL approve

Product Type : Automatic fire protection system

Frequency : 50 Hertz (HZ)

Color : RED

Novec 1230 Gas Flooding System - Server Room

Novec 1230 Gas Flooding System - Server Room

Price 250000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Material : CCOE / PESO approved

Product Type : Clean agent based Gas flooding system

Frequency : 50 Hertz (HZ)

Color : Red

FK-5-1-12 Gas Fire Suppression System

FK-5-1-12 Gas Fire Suppression System

Price 60000.0 INR / Set

Minimum Order Quantity : 1 Set

Material : CE Approved

Product Type : ELECTRICAL PANEL FIRE SUPPRESSION SYSTEM

Frequency : 50 Hertz (HZ)

Color : RED

Server Room Novec 1230 Fire Suppression System

Server Room Novec 1230 Fire Suppression System

Price 27500.0 INR / Set

Minimum Order Quantity : 1 Set

Material : Mild Steel

Product Type : Tube Based Fire Suppression System

Frequency : 50 Hertz (HZ)

Color : Red



Back to top