Fire Detection and Suppression System

Fire Detection and Suppression System
Fire Detection and Suppression System
Fire Detection and Suppression System

Fire Detection and Suppression System Specification

  • Installation Type
  • customized
  • Coverage Area
  • 1000 Square Meter (m2)
  • Color
  • RED
  • Mounting Type
  • customized
  • Connectivity Type
  • Auto+Manual
  • Technology
  • Imported
  • Frequency
  • 50 Hertz (HZ)
  • Alarm
  • YES
  • Warranty
  • 12 MONTHS
  • Shape
  • fire cylinder
  • Material
  • UL approve
  • Working Temperature
  • 68 Celsius (oC)
  • Control Type
  • auto
  • Fire Class
  • A,B and C
  • Operating Pressure
  • 25 Bar
  • Usage
  • fire suppression system
  • Features
  • Automatic fire suppression system
  • Dimension (L*W*H)
  • 1.2x.55x.55 Meter (m)
  • Fire Extinguisher Type
  • room flooding system
  • Weight
  • 200 Kilograms (kg)
  • Product Type
  • Automatic fire protection system
  • Input Power
  • 230 Volt (V)
  • Coating Type
  • crome
  • Energy Efficiency Rating
  • 5 star
  • Voltage
  • 24 Volt (v)
  • Temperature Range
  • 100 Celsius (oC)
  • Application
  • Server and data centers
  • Max Flow Rate
  • as per nfpa
  • Capacity
  • any Kg
  • Diameter
  • 1 Meter (m)
  • Pressure
  • 25 Bar
 

Fire Detection and Suppression System Trade Information

  • Minimum Order Quantity
  • 1 Set
  • FOB Port
  • Delhi
  • Payment Terms
  • Others
  • Supply Ability
  • 500 Sets Per Month
  • Delivery Time
  • 4 Week
  • Sample Available
  • No
  • Sample Policy
  • Within a certain price range free samples are available
  • Packaging Details
  • Standard
  • Main Domestic Market
  • All India
  • Certifications
  • UL/LPCB/FM/VDS/CE
 

About Fire Detection and Suppression System

Fire Detection & Suppression System for Server Room  

Fire Detection & Suppression System for Server Room is an advanced automatic fire protection solution designed to protect servers, data centers, IT rooms, cloud infrastructure, network racks, NOC rooms, and UPS areas from fire hazards without harming sensitive electronic equipment. The system combines early fire detection with rapid clean agent gas suppression, ensuring fast response, zero residue, and minimum downtime.


The system detects fire at the incipient stage using smoke detectors, heat detectors, or heat sensing tube technology and automatically releases clean agent gases such as Novec 1230 (FK-5-1-12) or FM-200 (HFC-227ea) through a total flooding or localized suppression system, quickly extinguishing the fire before it spreads.


Key Features

  • Integrated fire detection & automatic suppression for server rooms

  • Clean agent gas based system non-conductive & residue-free

  • Safe for live electrical & electronic equipment

  • Tube-based DLP / ILP options for server racks & cabinets

  • Fast response with high suppression efficiency

  • Low maintenance & reliable long-term performance


Applications

  • Server Rooms & Data Centers

  • Cloud Computing & IT Infrastructure

  • Network Operation Centers (NOC)

  • UPS & Battery Rooms

  • Telecom & Control Rooms


Standards & Compliance

  • Designed as per NFPA 2001 Clean Agent Fire Extinguishing Systems

  • ISO 14520 compliant

  • Meets Indian fire safety regulations


Trending & High-Search Keywords (TradeIndia / Google)

Server room fire detection and suppression system, data center fire suppression, clean agent fire suppression system, Novec 1230 fire suppression, FM200 gas flooding system, automatic fire suppression system, IT room fire protection, server rack fire suppression, gas based fire fighting system.



Superior Coverage and Efficiency

Ideal for server and data centers, this system efficiently covers areas up to 1000 square meters. Its 5-star energy efficiency rating ensures cost-effective operation without compromising on protection. Automatic detection and suppression allow rapid response to fire incidences, minimizing potential damage and downtime.


Advanced Customization and Control

Tailored to fit various installations, the system features both automatic and manual control, with user-defined mounting options. Operating reliably under 25 Bar pressure, it can adapt to unique room dimensions and specific site requirements. The chrome coating adds durability while maintaining a professional appearance.


UL-Approved Safety and Assurance

Constructed from UL-approved materials, this fire suppression system adheres to global safety standards. A comprehensive 12-month warranty covers users against manufacturing defects, and service provider support is readily available across India. Each unit undergoes rigorous testing for quality assurance.

FAQ's of Fire Detection and Suppression System:


Q: How does the fire detection and suppression system operate?

A: This system leverages auto and manual connectivity to monitor for signs of fire, activating the room flooding mechanism when heat or smoke is detected. It provides rapid suppression for Class A, B, and C fires, ensuring minimized risk in protected spaces.

Q: What are the installation and mounting options available?

A: Installation is fully customized according to your site's needs, with support for various mounting types. Dealer, distributor, and service provider teams in India assist with assessment and on-site setup to ensure optimal system performance.

Q: When should the system be serviced or maintained?

A: Routine checks are recommended at intervals specified in the manufacturer's guidelines-typically every 6 to 12 months. Regular servicing ensures all components, including the fire cylinder and alarm, remain in peak operating condition throughout the warranty period and beyond.

Q: Where is this fire suppression system most effectively used?

A: This system is designed specifically for environments with high-value electronic assets, such as server rooms and data centers, where quick, efficient fire mitigation is critical to safety and business continuity.

Q: What benefits does the automatic fire suppression feature offer?

A: The automatic feature ensures immediate response to fire, significantly reducing the likelihood of damage and operational disruption. The rapid room flooding process provides comprehensive coverage, even in complex technological environments.

Q: How energy efficient is the system during operation?

A: With a 5-star energy efficiency rating, the system operates economically, using only the necessary power (24V running voltage; 230V input) for monitoring and activation, without excessive energy consumption.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Server & Data center fire suppression system Category

Fire Novec 1230 Fire Suppression Systems

Fire Novec 1230 Fire Suppression Systems

Price 80000.00 INR / Set

Minimum Order Quantity : 1 Set

Warranty : 12 MONTHS

Material : Metal Alloy

Application : ELECTRICAL Panels

Color : RED

Electrical Novec Gas Suppression System

Electrical Novec Gas Suppression System

Price 200000.00 INR / Set

Minimum Order Quantity : 1 Set

Warranty : 12 MONTHS

Material : UL APPROVED

Application : SERVER ROOM/ ELECTRICAL ROOM

Color : RED

Novec 1230 Fire Protection System

Novec 1230 Fire Protection System

Price 55000.00 INR / Set

Minimum Order Quantity : 1 Set

Warranty : 12 MONTHS

Material : CE Approved

Application : electrical panel, server rack, electrical enclosure

Color : RED

Gas Suppression System

Gas Suppression System

Price 65000.00 INR / Set

Minimum Order Quantity : 1 Set

Warranty : 12 MONTHS

Material : CE Approved

Application : ELECTRICAL PANELS

Color : RED



Back to top