Novec 1230 Gas Flooding System - Server Room

Novec 1230 Gas Flooding System - Server Room
Novec 1230 Gas Flooding System - Server Room
Novec 1230 Gas Flooding System - Server Room
Novec 1230 Gas Flooding System - Server Room
Novec 1230 Gas Flooding System - Server Room
Novec 1230 Gas Flooding System - Server Room
Novec 1230 Gas Flooding System - Server Room

Novec 1230 Gas Flooding System - Server Room Specification

  • Dimension (L*W*H)
  • 1.5x1x1 Meter (m)
  • Material
  • CCOE / PESO approved
  • Temperature Range
  • 68 Celsius (oC)
  • Operating Pressure
  • 25/42 Bar
  • Input Power
  • 24 Volt (V)
  • Installation Type
  • customize
  • Coverage Area
  • entire Square Meter (m2)
  • Alarm
  • yes
  • Product Type
  • Clean agent based Gas flooding system
  • Warranty
  • 1 Yeas
  • Mounting Type
  • floor
  • Energy Efficiency Rating
  • 5
  • Voltage
  • 24 Volt (v)
  • Usage
  • Industrial and commercial
  • Working Temperature
  • 68 Celsius (oC)
  • Connectivity Type
  • standard
  • Fire Extinguisher Type
  • Total room flooding system
  • Weight
  • 150 Kilograms (kg)
  • Fire Class
  • A,B,C
  • Shape
  • fire cylinder
  • Features
  • automatic
  • Technology
  • total flooding system
  • Color
  • Red
  • Control Type
  • solenoid
  • Coating Type
  • crome
  • Frequency
  • 50 Hertz (HZ)
  • Application
  • Gas flooding system in Server area
  • Max Flow Rate
  • as per NFPA/VDS
  • Diameter
  • any Meter (m)
  • Capacity
  • 34/80/120/140 Ltr
  • Pressure
  • 25/42 Bar
 

Novec 1230 Gas Flooding System - Server Room Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 20 Pieces Per Month
  • Delivery Time
  • 5 Week
  • Packaging Details
  • Standard
  • Main Domestic Market
  • All India
  • Certifications
  • UL / VDS
 

About Novec 1230 Gas Flooding System - Server Room

Novec 1230 Gas Flooding System for Server Room Clean Agent Fire Protection

The Novec 1230 Gas Flooding System for Server Rooms is an advanced automatic fire suppression solution designed to protect servers, IT equipment, and critical data infrastructure from fire hazards without causing damage or downtime.


This system uses Novec 1230 (FK-5-1-12) clean agent, which suppresses fire rapidly by absorbing heat and stopping combustion at the molecular level. The agent is non-conductive, residue-free, and safe for sensitive electronic equipment, ensuring zero data loss and quick system recovery after discharge.


The Novec 1230 gas flooding system works on the total flooding principle, where the agent is discharged through engineered nozzles to uniformly fill the protected server room. The system activates automatically through smoke detectors, heat detectors, or fire alarm panels, providing early fire detection and rapid suppression.


Key Features

  • Automatic clean agent gas flooding system

  • Safe for servers & live electrical equipment

  • No residue, no corrosion, no secondary damage

  • Fast fire knockdown with high efficiency

  • Environment friendly (zero ODP, very low GWP)

  • Minimal downtime and low maintenance


Applications

  • Server rooms & data centers

  • Network operation centers (NOC)

  • IT & telecom rooms

  • UPS & battery rooms

  • Control rooms & data storage areas


Compliance

  • Designed as per NFPA 2001 / ISO 14520

  • UL / ISO compliant system components


Keywords 

Novec 1230 gas flooding system server room, server room fire suppression system, clean agent fire suppression for server rooms, FK-5-1-12 fire suppression system, Novec 1230 fire protection system, data center gas suppression system.



Comprehensive Fire Protection for Server Rooms

The Novec 1230 Gas Flooding System offers robust protection specifically tailored for server environments. Total flooding technology ensures that your entire server area is covered, effectively safeguarding sensitive equipment from fire while minimizing downtime. With fast activation, this solution meets stringent standards for reliability and efficacy.


Customizable Installation and Versatile Applications

Whether your requirement is for a small server rack or an entire data centre, the system's customizable installation supports various configurations. It operates at an input of 24V and fits seamlessly with floor mounting, making it suitable for a wide array of industrial and commercial spaces where uninterrupted operation is crucial.


Certified Safe and Energy Efficient

Holding certifications like CCOE / PESO and featuring a 5-star energy efficiency rating, the Novec 1230 system guarantees both safety and sustainability. Its advanced alarm technology and automatic operation provide dependable fire detection and suppression without risking the environment or business operations.

FAQ's of Novec 1230 Gas Flooding System - Server Room:


Q: How does the Novec 1230 Gas Flooding System operate in a server room?

A: The system utilizes a total flooding process controlled by a solenoid mechanism, automatically releasing Novec 1230 gas throughout the covered area upon fire detection. It swiftly suppresses fires in Classes A, B, and C, providing thorough protection for server equipment without damaging electronics.

Q: What is the installation process for this system and can it be customized?

A: The installation is fully customizable to fit server rooms of any size or layout. The floor-mounted fire cylinders are positioned according to your space requirements, and the system is set up to integrate seamlessly with existing infrastructure and detection systems.

Q: Where can the Novec 1230 system be used?

A: This system is suitable for industrial and commercial environments, especially server rooms and data centres. Its flexible design accommodates coverage for any square meter area in United Kingdom businesses or facilities requiring advanced fire suppression.

Q: What are the key benefits of using Novec 1230 in server areas?

A: Novec 1230 provides rapid, clean fire suppression without leaving harmful residues, protecting sensitive electronics and minimizing operational downtime. The system is energy efficient, approved for safety, and ensures comprehensive coverage and automatic response for peace of mind.

Q: When does the system activate in case of fire?

A: The Novec 1230 Gas Flooding System is equipped with automatic detection and alarm capabilities. Upon identifying smoke or heat indicative of a fire, the system activates immediately to flood the affected area and quickly extinguish the fire.

Q: How is the safety and compliance of the Novec 1230 system ensured?

A: The system is CCOE / PESO approved and meets globally recognised standards such as those defined by NFPA and VdS. This guarantees that it operates within safe pressure (25/42 Bar) and temperature (68C) levels, ensuring reliable and compliant performance.

Q: What maintenance and warranty services are available?

A: The Novec 1230 Gas Flooding System comes with a 1-year warranty. Professional service, maintenance, and support are provided through a network of authorized dealers, distributors, and service providers across the United Kingdom.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Server & Data center fire suppression system Category

Fire Detection and Suppression System

Fire Detection and Suppression System

Price 155000.0 INR / Piece

Minimum Order Quantity : 1 Set

Usage : fire suppression system

Color : RED

Application : Server and data centers

Product Type : Automatic fire protection system

Server & Data center fire gas suppression system

Server & Data center fire gas suppression system

Price 250000.0 INR / Set

Minimum Order Quantity : 1 Piece

Usage : Industrial and commercial

Color : Red

Application : Fire Fighting Gas flooding system

Product Type : Clean agent gas suppression system

Novec 1230 Fire Protection System

Novec 1230 Fire Protection System

Price 55000.00 INR / Set

Minimum Order Quantity : 1 Set

Usage : fire suppression system

Color : RED

Application : electrical panel, server rack, electrical enclosure

Product Type : Novec 1230 fire protection system

Gas Suppression System

Gas Suppression System

Price 65000.00 INR / Set

Minimum Order Quantity : 1 Set

Usage : fire suppression system

Color : RED

Application : ELECTRICAL PANELS

Product Type : ELECTRICAL PANEL FIRE SUPPRESSION SYSTEM



Back to top