Tube based gas suppression system

Tube based gas suppression system
Tube based gas suppression system
Tube based gas suppression system
Tube based gas suppression system

Tube based gas suppression system Specification

  • Dimension (L*W*H)
  • 1 x 1 x 0.8 Meter (m)
  • Mounting Type
  • wall/ panel
  • Input Power
  • 230 Volt-Ampere (VA)
  • Warranty
  • 18 Month
  • Alarm
  • 100 DB
  • Usage
  • Fire suppression
  • Operating Pressure
  • 15 PSI
  • Coating Type
  • Crome
  • Voltage
  • 5 Ampere (amp)
  • Product Type
  • Automatic tube suppression
  • Coverage Area
  • 4 Square Meter (m2)
  • Technology
  • Automatic
  • Temperature Range
  • 100 Celsius (oC)
  • Fire Extinguisher Type
  • clean agent
  • Features
  • standalone
  • Frequency
  • 50 Hertz (HZ)
  • Working Temperature
  • 100 Celsius (oC)
  • Fire Class
  • B & C
  • Color
  • red
  • Connectivity Type
  • No/ Nc
  • Shape
  • cylindrical
  • Control Type
  • Automatic
  • Material
  • UL approved
  • Installation Type
  • On Site
  • Weight
  • 15 Kilograms (kg)
  • Application
  • Electrical cabinate
  • Max Flow Rate
  • 0.67/ sec
  • Capacity
  • any Kg
  • Diameter
  • 6 Millimeter (mm)
  • Pressure
  • 15 PSI
 

Tube based gas suppression system Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • FOB Port
  • Delhi
  • Payment Terms
  • Cheque
  • Supply Ability
  • 250 Units Per Month
  • Delivery Time
  • 2 Week
  • Sample Available
  • No
  • Sample Policy
  • Within a certain price range free samples are available
  • Packaging Details
  • standard
  • Main Export Market(s)
  • Asia
  • Main Domestic Market
  • All India, South India, Central India, West India, North India, East India
  • Certifications
  • UL Approved and CE Approved products available
 

About Tube based gas suppression system

A Tube-Based Fire Suppression System is a pre-engineered, automatic fire protection solution designed to detect and extinguish fires directly at the source. It uses a flexible polymer detection tube pressurized with a clean agent or CO. The tube itself acts as both the fire detector and discharge mechanism.

When exposed to rising heat or flame, the tube ruptures precisely at the hottest point, releasing the extinguishing agent directly onto the fire. This ensures fast, localized suppression before the fire can spread.

Key Features:

  • Automatic Operation Works without power or electronics.

  • Direct & Fast Suppression Agent discharges at the exact fire spot.

  • Compact & Reliable Ideal for confined or enclosed hazards.

  • Versatile Agents Can use Clean Agents (FK-5-1-12, Novec 1230, FM-200) or CO depending on application.

  • Zero Downtime No complex piping or room sealing required.

Applications:

  • Electrical panels, MCCs, VCBs

  • CNC & precision machines

  • Server racks, data cabinets

  • Vehicles & mining equipment

  • Kitchen hoods & small enclosures

Benefits:

  • Early Fire Detection & Suppression at the source

  • Minimal Damage Only the affected area is discharged

  • Safe & Clean No residue when using clean agents

  • Cost-Effective Simple design, low maintenance



Tube Based Fire Suppression System Compact & Effective


A Tube Based Fire Suppression System is a compact, automatic, and highly effective fire protection solution designed to safeguard critical equipment in confined spaces. Using heat-sensitive polymer tubing, the system detects and suppresses fire directly at the source, ensuring rapid response and minimal damage.

Ideal for electrical panels, server racks, vehicles, CNC machines, and engine compartments, this system works without electricity or human intervention, making it reliable even in remote or unmanned locations.



Advanced Fire Protection for Critical Equipment

This tube-based gas suppression system leverages automatic technology to instantly address Class B and C fires in electrical cabinets. Designed to deliver quick-response fire extinguishing, the system activates upon detecting high temperatures, ensuring both personnel and sensitive electronics are safeguarded from fire damage.


User-Friendly Installation and Operation

Installation is straightforward: mount the cylindrical system on a wall or inside a panel, connect to a 230 VA power source, and it works as a standalone unit. With a distinctive 100 dB alarm and visual alerts, users receive instant notifications during activation, minimizing response time and reducing risk.

FAQ's of Tube based gas suppression system:


Q: How does the tube-based gas suppression system detect and suppress fires in electrical cabinets?

A: The system uses automatic sensing technology to detect high temperatures inside the cabinet. When the temperature reaches 100C, the pressurized clean agent is released via the UL-approved tube, rapidly extinguishing the fire and emitting a 100 dB alarm for immediate awareness.

Q: What types of fires can this suppression system handle, and where is it best applied?

A: The system is suitable for Class B and C fires-typically those involving flammable liquids, gases, and electrical equipment. It is engineered specifically for electrical cabinets and can be installed in control panels within commercial, industrial, or server environments.

Q: When is maintenance required for this gas suppression system, and what does it involve?

A: Routine maintenance is recommended every six months to ensure the system remains fully operational. This involves checking the mounting, verifying the alarm and indicator functions, and ensuring the agent's pressure and tube integrity are within specifications.

Q: What benefits does using a clean agent provide for electrical fire suppression?

A: A clean agent extinguishes fires without leaving residue or causing electrical damage, making it ideal for sensitive equipment. This ensures minimal downtime and eliminates cleanup, preserving critical hardware and reducing business interruption.

Q: Where should the tube-based gas suppression system be installed for optimal effectiveness?

A: It should be mounted directly on the wall or inside the electrical panel, ideally near potential fire sources within the cabinet. Coverage extends up to 4 square meters, allowing precise placement for targeted suppression of critical locations.

Q: What is the process for activating and resetting the system after it has been triggered?

A: Activation occurs automatically upon detecting high temperatures. To reset post-activation, the system must be inspected, the extinguished agent replaced, and all components checked for pressure and integrity before rearming and reinstalling the unit.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Electrical Cabinet Fire protection System Category

Electrical Panel Novec 1230 Gas Flooding System

Electrical Panel Novec 1230 Gas Flooding System

Price 50000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Material : Mild Steel

Weight : 15 Kilograms (kg)

Color : Red

Temperature Range : 110 Celsius (oC)

Fire Extinguisher For Electrical Panels and Room

Fire Extinguisher For Electrical Panels and Room

Price 50000.0 INR / Piece

Minimum Order Quantity : 1 Set

Material : UL APPROVED

Weight : 20 Kilograms (kg)

Color : red

Temperature Range : 100 Celsius (oC)

Electrical Panel Fire Suppression System

Electrical Panel Fire Suppression System

Price 45000.0 INR / Unit

Minimum Order Quantity : 1 Set

Material : Metal Alloy

Weight : 10 Kilograms (kg)

Color : Red

Temperature Range : 100 Celsius (oC)

Tube Based Gas Fire Protection System

Tube Based Gas Fire Protection System

Price 50000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Material : Mild Steel

Weight : 12 Kilograms (kg)

Color : Red

Temperature Range : 110 Celsius (oC)



Back to top