FM200 Gas Flooding System is an automatic clean agent total flooding fire suppression system designed to protect enclosed rooms containing sensitive electrical, electronic and high value equipment. The system uses FM200 HFC 227ea clean agent and is suitable for applications where rapid fire suppression is required without water discharge.
The FM200 Gas Flooding System operates through an automatic fire detection and releasing system. Smoke or heat detectors continuously monitor the protected area. When the configured fire condition is detected, the releasing control panel initiates the suppression sequence and the calculated quantity of FM200 is discharged through a network of FM200 piping and discharge nozzles to achieve the required extinguishing concentration throughout the protected enclosure.
Application Areas: Server Room, Data Center, IT Room, Telecom Room, Network Room, NOC Room, Control Room, SCADA Room, Electrical Room, UPS Room, Battery Room, Switchgear Room, Relay Room, GIS Room, Substation Room, Automation Room, Laboratory, Cleanroom, Archive Room, Control Center and Critical Equipment Room.
Equipment Protection: Server Racks, Network Equipment, Communication Equipment, Storage Systems, UPS Systems, Electrical Panels, PLC Systems, Control Electronics, Automation Equipment, Switchgear, Power Electronics, Telecom Equipment and other sensitive electronic equipment as applicable to the system design.
Main Components: FM200 HFC 227ea Cylinder, FM200 Release Valve, Releasing Fire Alarm Control Panel, Smoke Detectors, Heat Detectors, FM200 Discharge Nozzles, Pressure Switch, Manual Release Station, Abort Switch where applicable, Alarm Hooter, Strobe Light, Time Delay Unit, FM200 Discharge Piping, Warning Signage and Interface Modules.
Key Features: Automatic Fire Detection, FM200 Gas Flooding, Total Flooding Fire Suppression, Fast Fire Response, No Water Damage, Low Residue Protection, Sensitive Electronics Protection, Automatic and Manual Release, Fire Alarm Integration, Equipment Shutdown Interface and Application Specific Nozzle Design.
Working Principle: Smoke and heat detectors identify a fire condition and transmit the signal to the releasing control panel. After the configured release sequence, the FM200 cylinder valve operates and the clean agent flows through the distribution piping and discharge nozzles. The system is engineered to provide the required agent concentration throughout the protected room.
Total Flooding Protection: The FM200 system is designed for enclosed spaces where the clean agent can be retained at the required concentration. Proper room integrity, door seals, ventilation shutdown, damper closure, pressure relief and enclosure conditions should be considered during system design.
Suitable Industries: Data Centers, IT Facilities, Telecom Facilities, Banking and Finance, Hospitals, Power Plants, Electrical Substations, Manufacturing Industries, Pharmaceutical Industries, Chemical Industries, Oil and Gas Facilities, Railway Systems, Airports, Renewable Energy Projects and Critical Infrastructure.
System Design: The required FM200 agent quantity, cylinder capacity, cylinder quantity, pipe size, nozzle quantity, nozzle location and discharge time should be calculated according to the protected room volume, fire hazard, enclosure integrity, ventilation, occupancy and applicable system design requirements.
For engineered installations, NFPA 2001 may be considered as a design reference where applicable, together with manufacturer specifications, project requirements and local fire safety regulations.
Fire Engineering Technology provides FM200 Gas Flooding Systems, FM200 Total Flooding Fire Suppression Systems, HFC 227ea Clean Agent Systems, Server Room Gas Suppression Systems, Data Center Fire Protection Systems and Electrical Room Fire Suppression Systems with design, engineering, supply, installation, testing, commissioning, maintenance, AMC and refilling services across India.
High Search Keywords: FM200 Gas Flooding System, FM 200 Gas Flooding System, FM200 Flooding System, FM200 Total Flooding System, FM200 Gas Fire Suppression System, FM200 Clean Agent Fire Suppression, FM200 HFC 227ea Fire Suppression System, FM200 Fire Fighting System, Automatic FM200 Gas Flooding System, FM200 Room Flooding System, FM200 Server Room Fire Suppression, FM200 Data Center Fire Suppression, FM200 UPS Room Fire Suppression, FM200 Electrical Room Fire Suppression, FM200 Telecom Room Fire Suppression, FM200 Control Room Fire Suppression, FM200 Switchgear Room Fire Suppression, FM200 Substation Fire Protection, HFC 227ea Gas Flooding System, Clean Agent Gas Flooding System, Automatic Gas Fire Suppression System, Total Flooding Clean Agent System, FM200 Fire Protection System Manufacturer India, FM200 Gas Flooding System Supplier India.


Price:
Price 450000.0 INR / Set
Minimum Order Quantity : 1 Set
Weight : 1150 Kilograms (kg)
Dimension (L*W*H) : 2x1x1 Meter (m)
Application : Server Room/ Network Room/ Chemical storage
Temperature Range : 100 Celsius (oC)
Price 150000.0 INR / Piece
Minimum Order Quantity : 1 Piece
Weight : 150 Kilograms (kg)
Dimension (L*W*H) : 2x1x1 Meter (m)
Application : FIRE PROTECTION Automatic gas flooding system
Temperature Range : 90120 Celsius (oC)
Price 55000.0 INR / Piece
Minimum Order Quantity : 1 Set
Weight : 25 Kilograms (kg)
Dimension (L*W*H) : 1x1x1 Meter (m)
Application : FIRE FIGHTING UPS and Battery Room
Temperature Range : 100120 Celsius (oC)
Price 250000.0 INR / Set
Minimum Order Quantity : 1 Set
Weight : 150 Kilograms (kg)
Dimension (L*W*H) : 1.5X1X1 Meter (m)
Application : FIRE FIGHTING GAS FLOODING SYSTEM
Temperature Range : 2168 Celsius (oC)