Clean Agent Based Fire Extinguishing System Specification

  • Temperature Range
  • 100 Celsius (oC)
  • Alarm
  • YES
  • Material
  • UL APPROVED
  • Installation Type
  • standard
  • Fire Extinguisher Type
  • total gas flooding system
  • Energy Efficiency Rating
  • 5 star
  • Features
  • automatic gas flooding system
  • Control Type
  • Mechanical and solenoid
  • Color
  • RED
  • Technology
  • Total flooding system
  • Product Type
  • Clean agent fire extinguishing system
  • Input Power
  • 230 Volt (V)
  • Usage
  • GAS SUPPRESSION SYSTEM
  • Connectivity Type
  • solenoid
  • Working Temperature
  • 68 Celsius (oC)
  • Warranty
  • 12 MONTHS
  • Coverage Area
  • entire room Square Meter (m2)
  • Mounting Type
  • floor
  • Dimension (L*W*H)
  • 2x1x1 Meter (m)
  • Fire Class
  • A,B,C
  • Frequency
  • 50 Hertz (HZ)
  • Voltage
  • 24/230 Volt (v)
  • Coating Type
  • crome
  • Shape
  • fire cylinders
  • Weight
  • 1-150 Kilograms (kg)
  • Operating Pressure
  • 25/42 Bar
  • Application
  • Server Room/ Network Room/ Chemical storage
  • Max Flow Rate
  • As per NFPA design
  • Capacity
  • 1-150 Kg
  • Diameter
  • any Meter (m)
  • Pressure
  • 25/42 Bar
 

Clean Agent Based Fire Extinguishing System Trade Information

  • Minimum Order Quantity
  • 1 Set
  • FOB Port
  • Mumbai
  • Supply Ability
  • 10 Sets Per Month
  • Delivery Time
  • 4 Week
  • Sample Policy
  • Contact us for information regarding our sample policy
  • Main Domestic Market
  • All India
  • Certifications
  • ul
 

About Clean Agent Based Fire Extinguishing System

Clean Agent Based Fire Extinguishing System  

The Clean Agent Based Fire Extinguishing System is a modern, high-performance automatic fire suppression system designed to protect sensitive, high-value, and mission-critical assets without using water, foam, or powder. This advanced clean agent fire suppression system extinguishes fire rapidly while leaving no residue, ensuring zero damage to electrical and electronic equipment.

A clean agent fire extinguishing system works by absorbing heat and interrupting the chemical chain reaction of fire, providing fast and effective fire suppression at the incipient stage. It is widely used as a Halon replacement fire suppression system, fully compliant with current environmental and fire safety standards.


 Key Features & Benefits

  • Automatic Fire Detection & Suppression System

  • Residue-Free Clean Agent Technology no clean-up required

  • Safe for Occupied Areas at design concentration

  • Non-Conductive & Non-Corrosive ideal for electronics

  • Fast Discharge & Quick Fire Knock-Down

  • Eco-Friendly Fire Suppression Solution

  • Low Maintenance & High Reliability

  • NFPA 2001 / IS 15493 / NBC Compliant Design


 Common Clean Agents Used

  • FK-5-1-12 (Novec 1230) Fire Suppression System

  • FM-200 (HFC-227ea) Clean Agent System

  • Inert Gas Systems (IG-541, IG-55, IG-100)


 Applications

  • Data Center & Server Room Fire Suppression System

  • Electrical & Control Panel Fire Protection

  • UPS & Battery Room Fire Suppression

  • Telecom & Switch Rooms

  • Banks, Hospitals & Laboratories

  • Museums, Archives & Libraries

  • Industrial Control Rooms & SCADA Systems


The clean agent based fire extinguishing system is ideal for environments where business continuity, equipment safety, and minimal downtime are critical. It integrates seamlessly with fire alarm panels, smoke detectors, heat detectors, manual release units, and abort switches, providing a complete automatic fire detection and suppression solution.


Search Keywords 

clean agent based fire extinguishing system, clean agent fire suppression system India, automatic clean agent fire suppression system, Novec 1230 clean agent fire suppression, FM-200 fire suppression system, gas based fire extinguishing system, residue free fire suppression system, fire suppression system for data centers, electrical panel clean agent fire suppression, NFPA 2001 compliant fire suppression system, IS 15493 clean agent fire protection.



Advanced Gas Suppression Technology

Utilizing total flooding technology, this clean agent system swiftly disperses gas to extinguish Class A, B, and C fires without leaving any residue. Designed for quick response, the automatic gas release protects sensitive equipment in server and network rooms. The system's solenoid connectivity and mechanical control ensure seamless integration with alarm and detection networks, maximizing safety and minimizing downtime.


User-Friendly and Reliable Installation

Mounted directly on the floor, these fire cylinders are designed for effortless installation and maintenance. Built to operate within a temperature range up to 100C, the system suits various environments. Engineered with UL-approved materials and chrome coating, users enjoy robust performance and a year-long warranty for peace of mind. The product's energy efficiency also helps reduce running costs.

FAQ's of Clean Agent Based Fire Extinguishing System:


Q: How does the clean agent fire extinguishing system operate during a fire emergency?

A: The system employs total flooding technology, automatically releasing a clean agent gas when heat or fire is detected. The quick response ensures complete coverage of the designated room, suppressing Class A, B, and C fires efficiently. It works through mechanical or solenoid control, activating alarms and triggering gas discharge as per NFPA guidelines.

Q: What areas and applications is this system best suited for?

A: This extinguishing system is specifically designed for use in server rooms, network rooms, and chemical storage facilities. Its ability to protect sensitive electronic equipment and hazardous materials makes it ideal for these environments, ensuring that fires are quickly neutralized with minimal disruption or equipment damage.

Q: When should the clean agent system be installed in a facility?

A: Installation is recommended during the establishment or major upgrade of critical areas, such as new server rooms, data centers, or chemical storage units. Retrofitting is also possible whenever enhanced fire protection is needed, ensuring compliance with safety standards and safeguarding valuable assets.

Q: Where within a room should the extinguishing cylinders be placed?

A: Cylinders should be floor-mounted in accordance with NFPA design, ensuring they provide coverage for the entire room. Placement optimizes gas dispersion and ensures effective suppression in all protected areas, tailored to room size and hazards.

Q: What is the process for activating and maintaining the system?

A: Activation can be automatic via heat or smoke detection, or manually if needed. Maintenance involves routine inspections, checking cylinder pressure (25/42 bar), ensuring solenoid connections, and verifying alarm systems, all as per UL and NFPA standards. Annual servicing is recommended to uphold warranty and performance.

Q: How can users benefit from installing a clean agent gas suppression system?

A: Users benefit from rapid fire suppression that leaves no residue and minimizes damage to electronics and critical infrastructure. The 5-star energy efficiency rating reduces operating costs, and the system's automatic operation means minimal manual intervention, contributing to enhanced safety and business continuity.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Gas Suppression system Category

Automatic Novec 1230 Gas Flooding System

Automatic Novec 1230 Gas Flooding System

Price 250000.0 INR / Set

Minimum Order Quantity : 1 Set

Alarm : yes

Material : seamless steel

Color : Red

Application : FIRE FIGHTING GAS FLOODING SYSTEM

FM 200 Gas Flooding System

FM 200 Gas Flooding System

Price 250000 INR / Piece

Minimum Order Quantity : 1 Piece

Alarm : Yes

Material : Seamless steel

Color : Red

Application : Ansul System FM 200 gas flooding system

FM 200 Gas Flooding System

FM 200 Gas Flooding System

Price 40000.0 INR / Set

Minimum Order Quantity : 1 Piece

Alarm : yes

Material : UL approved

Color : Red

Application : FIRE PROTECTION FM200 gas flooding system

Fire Gas Suppression System

Fire Gas Suppression System

Price 50000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Alarm : yes

Material : Gas suppression

Color : red

Application : Automatic gas suppression system



Back to top