Electric Panel Gas Flooding System Specification

  • Weight
  • 15 Kilograms (kg)
  • Working Temperature
  • 100-120 Celsius (oC)
  • Coating Type
  • crome
  • Features
  • tube based automatic fire suppression
  • Input Power
  • Volt (V)
  • Dimension (L*W*H)
  • 1x1x1 Meter (m)
  • Shape
  • fire extinguishers
  • Control Type
  • Mechanical
  • Fire Extinguisher Type
  • tube based fire suppression
  • Mounting Type
  • wall/ skid
  • Temperature Range
  • 100-120 Celsius (oC)
  • Connectivity Type
  • standard
  • Voltage
  • Volt (v)
  • Frequency
  • 50 Hertz (HZ)
  • Usage
  • ELECTRICAL PANEL
  • Material
  • Mild Steel
  • Operating Pressure
  • 15-18 Bar
  • Product Type
  • Electric Panel Gas Flooding System
  • Energy Efficiency Rating
  • 5
  • Warranty
  • 12 months
  • Coverage Area
  • Entire cabinet Square Meter (m2)
  • Alarm
  • yes
  • Color
  • Red
  • Installation Type
  • customize
  • Fire Class
  • A,B,C
  • Technology
  • Direct and Indirect fire protection
  • Application
  • Fire Protection System - Fire suppression
  • Max Flow Rate
  • As per NFPA 2001
  • Diameter
  • 4/6 Millimeter (mm)
  • Capacity
  • 1-9 Kg
  • Pressure
  • 15-18 Bar
 

Electric Panel Gas Flooding System Trade Information

  • Minimum Order Quantity
  • 1 Set
  • Supply Ability
  • 500 Sets Per Month
  • Delivery Time
  • 4 Week
 

About Electric Panel Gas Flooding System

Electric Panel Gas Flooding System  

The Electric Panel Gas Flooding System is an advanced automatic fire detection and suppression system specially designed to protect electrical panels, LT/HT panels, PCC panels, MCC panels, control panels, PLC panels, and distribution boards from fire hazards. This gas based fire suppression system uses clean agent or gaseous extinguishing media to suppress fire quickly without damaging sensitive electrical and electronic components.

An electrical panel gas flooding fire suppression system works on the total flooding principle, where the protected enclosure is rapidly filled with a clean extinguishing gas to extinguish fire at its early stage. The system is fully automatic and activates through smoke or heat detection, ensuring instant fire suppression inside the panel enclosure before the fire spreads.


 Key Features & Benefits

  • Automatic Gas Flooding Fire Suppression for electrical panels

  • Clean Agent & Residue-Free System no powder, no water, no cleanup

  • Safe for Electrical & Electronic Equipment non-conductive and non-corrosive

  • Fast Fire Knock-Down within seconds

  • Compact & Space-Saving Design suitable for panel enclosures

  • Minimal Downtime and protection of costly assets

  • NFPA 2001 / IS 15493 / NBC Compliant Design


Gases Commonly Used

  • FK-5-1-12 (Novec 1230) Electrical Panel Fire Suppression System

  • FM-200 (HFC-227ea) Gas Flooding System

  • CO Gas Flooding System (for unoccupied panels)


Applications

  • LT & HT Electrical Panels

  • MCC / PCC / APFC Panels

  • PLC & Automation Control Panels

  • UPS & Battery Panel Enclosures

  • Industrial Control Panels

  • Server Rack Power Panels & Telecom Panels

The electric panel gas flooding system is a proven Halon replacement fire protection solution and is widely used in industries where electrical fire safety, business continuity, and equipment protection are critical. The system integrates seamlessly with fire alarm panels, smoke detectors, heat detectors, manual release units, and abort switches, providing reliable automatic fire protection for electrical panels.


Search Keywords 

electric panel gas flooding system, electrical panel fire suppression system, gas fire suppression for electrical panels, clean agent fire suppression system for panels, automatic electrical panel fire protection system, FM-200 electrical panel fire suppression, Novec 1230 panel fire suppression system, CO2 gas flooding electrical panel, control panel gas fire suppression, NFPA 2001 compliant fire suppression system, IS 15493 electrical panel fire protection.




Comprehensive Fire Suppression for Electrical Panels

Protect your valuable electrical equipment with our tube-based fire suppression system. Engineered for both direct and indirect fire protection, it safeguards entire panel cabinets from different fire classes. Quick-acting and customizable to fit unique installation requirements, the system delivers peace of mind with reliable performance in high-temperature environments.


Advanced Safety Features and Custom Installation

Equipped with a built-in alarm, mechanical controls, and a 5-star energy efficiency rating, this system is designed for seamless integration within industrial settings. You can choose from wall or skid mounting, and the setup is tailored to each specific electrical cabinet, ensuring perfect fit and optimal coverage for maximum safety.

FAQ's of Electric Panel Gas Flooding System:


Q: How does the tube-based automatic fire suppression system work in electrical panels?

A: The system uses a specialized detection tube that bursts when exposed to fire or extreme heat (100-120C), releasing the extinguishing agent directly at the source of the fire. This rapid intervention limits damage and ensures quick fire suppression within your electrical panel.

Q: What types of fires can this system extinguish in electrical panels?

A: It is designed to suppress Class A, B, and C fires, making it effective against ordinary combustibles, flammable liquids, and electrical fires. This makes it particularly suitable for guarding critical power distribution units and control cabinets.

Q: When should the gas flooding system be installed in an electrical panel?

A: It is best to install the system during the setup of new electrical panels or during routine upgrades and maintenance. This ensures that the equipment is protected before any fire hazards can develop.

Q: Where can the Electric Panel Gas Flooding System be installed?

A: The system is engineered for installation inside electrical panels found in industrial, commercial, or data center environments across India. It can be wall-mounted or skid-mounted, and the coverage area can be customized to fully protect the specific cabinet dimensions.

Q: What is the installation process for the fire suppression system?

A: Installation involves mounting the detection tube inside the cabinet, connecting it to the extinguishing agent cylinder, and integrating the mechanical control and alarm systems. It is customized to fit your panel, ensuring optimal agent flow as per NFPA 2001 requirements.

Q: How is the system maintained for reliable operation?

A: Routine inspections and servicing are recommended, including checking tube integrity, pressure levels (15-18 Bar), and alarm functionality. Our units come with a 12-month warranty and guidance for regular maintenance to ensure dependable performance.

Q: What are the key benefits of using this gas flooding system for fire suppression?

A: This system provides rapid, automatic detection and suppression, reducing downtime, equipment loss, and fire-related hazards. Its energy-efficient design, compliance with leading fire safety standards, and customizable installation make it a cost-effective and robust safety solution for businesses.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Gas Suppression system Category

Automatic Gas Flooding System

Automatic Gas Flooding System

Price 150000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Features : fully automatic

Pressure : 25/42 Bar

Dimension (L*W*H) : 2x1x1 Meter (m)

Shape : PESO fire cylinders

Automatic Novec 1230 Gas Flooding System

Automatic Novec 1230 Gas Flooding System

Price 250000.0 INR / Set

Minimum Order Quantity : 1 Set

Features : automatic and manual

Pressure : 15/25/42 Bar

Dimension (L*W*H) : 1.5X1X1 Meter (m)

Shape : fire cylinders

CO2 Gas Flooding System

CO2 Gas Flooding System

Price 100000.0 INR / Set

Minimum Order Quantity : 1 Piece

Features : Auto and manual fire suppression

Pressure : 250 Bar

Dimension (L*W*H) : 2x1x1 Meter (m)

Shape : co2 fire cylinders

Gas Flooding and suppression System

Gas Flooding and suppression System

Price 100000.0 INR / Piece

Minimum Order Quantity : 1 Set

Features : auto and manual

Pressure : 15/25/42 Bar

Dimension (L*W*H) : 1.5x1x1 Meter (m)

Shape : fire cylinders



Back to top