Novec 1230 Gas Suppression System
Novec 1230 Gas Suppression System

Novec 1230 Gas Suppression System

Price 50000.00 INR/ Piece

MOQ : 1 Set

Novec 1230 Gas Suppression System Specification

  • Temperature Range
  • 20to + 55 Celsius (oC)
  • Features
  • Eco-friendly, Low Global Warming Potential, Fast action, Zero Ozone Depletion Potential, Electrically Non-conductive, Safe for Occupied Spaces
  • Operating Pressure
  • 25 bar or 42 bar depending on cylinder type
  • Connectivity Type
  • Compatible with Addressable Fire Alarm Panels
  • Fire Extinguisher Type
  • Clean Agent Fire Suppression System
  • Mounting Type
  • Floor standing or wall mounted cylinders
  • Fire Class
  • A, B, C
  • Control Type
  • Automatic and Manual
  • Product Type
  • Novec 1230 gas suppression system
  • Voltage
  • 24V DC (for control and release panel)
  • Color
  • Red
  • Working Temperature
  • -10C to +50C
  • Coating Type
  • Anti-corrosive powder coated cylinder
  • Installation Type
  • Ceiling and Wall Mounted / Modular or Centralized System
  • Technology
  • Clean Agent Gas Suppression System
  • Shape
  • Cylindrical
  • Material
  • Carbon Steel
  • Coverage Area
  • Customized as per site requirement, generally up to 800 m3 with modular configuration
  • Usage
  • Industrial
  • Application
  • Fire Protection in Data Centers, Server Rooms, Electrical Panels, Telecommunication Centers, Cleanrooms, Hospitals, Museums, Archives, and Industrial Facilities
  • Max Flow Rate
  • Up to 690 kg/min (system dependent)
  • Diameter
  • As per system requirement (typically ranges from 8 mm to 42 mm for pipes and nozzles)
  • Capacity
  • Modular cylinders starting from 9 kg to 370 kg and larger as per design
  • Pressure
  • 25 bar or 42 bar at 20C (depending on system design)
  • Cylinder Material
  • Seamless steel
  • Approval & Certification
  • UL, FM, LPCB, CE certified
  • Environmental Impact
  • Global warming potential <1, zero ozone depletion
  • Expected System Life
  • 30 years with regular maintenance
  • Nozzle Type
  • 360-degree multi-orifice discharge nozzle
  • Pipe Material
  • Corrosion-resistant galvanized steel
  • Noise Level During Discharge
  • Below 120 dB
  • System Reset Time
  • Minimal downtime, can be recharged onsite
  • Discharge Time
  • Less than 10 seconds
  • Agent Chemical Name
  • FK-5-1-12 (Novec 1230)
  • Storage Condition
  • Store indoors, away from direct sunlight
  • Discharge Pipe Size
  • 1 inch to 2.5 inches, based on system design
  • Service Interval
  • Annual inspection recommended
  • Alarm Integration
  • Compatible with addressable and conventional alarm panels
  • Leakage Detection
  • Optional gas leakage detector available
 

Novec 1230 Gas Suppression System Trade Information

  • Minimum Order Quantity
  • 1 Set
  • FOB Port
  • NEW DELHI
  • Supply Ability
  • 1000 Sets Per Month
  • Delivery Time
  • 4 Week
  • Sample Policy
  • Contact us for information regarding our sample policy
  • Packaging Details
  • Standard
  • Main Domestic Market
  • All India
  • Certifications
  • CE/LPCB/UL
 

About Novec 1230 Gas Suppression System

Novec 1230 gas suppression system is an inert gas fire suppression system designed to protect sensitive and valuable equipment from the hazards of fire. It works by releasing a cloud of Novec 1230 gas, which is an environmentally friendly gas that is odorless, colorless, and non-conductive. The gas works by quickly extinguishing the fire, while also cooling the affected area to prevent re-ignition. Novec 1230 is also effective in suppressing the spread of smoke and toxic gases, making it a popular choice for protecting data centers, server rooms, and other high-value areas.

Product details

  • Usage/Application : Industrial
  • Material : Carbon Steel
  • Brand : 3 M
  • Capacity : 20 Liters
  • Temperature : -20 Degree C to + 55 Degree C
  • Humidity : 95 %
  • Fire Class : B & C
  • Working Pressure : 25 Bar
  • Environment Temp : 21 Degree C



Advanced Clean Agent Fire Protection

Novec 1230 provides fast-acting fire suppression without causing damage to sensitive equipment or leaving residue. It's particularly suited for high-value areas like data centers and museums that require both asset protection and minimal downtime. Its electrically non-conductive properties make it safe for electronics, ensuring continuing operations after an incident.


Eco-Friendly and Safe for Occupied Spaces

With zero ozone depletion potential and a global warming potential (GWP) of less than 1, Novec 1230 is one of the most environmentally responsible solutions available. Approved for use in occupied spaces, it is in compliance with ISO 14520 and NFPA 2001, demonstrating commitment to both human and environmental safety.


Flexible Installation and Easy Maintenance

The system offers modular or centralized installation configurations, supporting coverage areas up to 800 m3. Cylinders are available with anti-corrosive powder coating in floor-standing or wall-mounted options, and all sizes support easy refilling. Maintenance is streamlined due to its long agent shelf life and compatibility with addressable fire alarm panels.

FAQ's of Novec 1230 Gas Suppression System:


Q: How does the Novec 1230 Gas Suppression System operate during a fire incident?

A: Upon detection of smoke or heat, the system automatically discharges Novec 1230 agent within ten seconds through 180 or 360 nozzles, quickly suppressing fires without harming sensitive equipment or occupants.

Q: What types of facilities are best protected by Novec 1230 systems?

A: This system is ideal for environments where asset protection and minimal collateral damage are critical, such as data centers, server rooms, electrical panels, telecommunication centers, cleanrooms, hospitals, museums, and archives.

Q: When should the Novec 1230 cylinders be inspected or refilled?

A: Cylinders should be inspected regularly according to the manufacturer's and installer's maintenance schedule, especially after any discharge event. Refilling is available for all cylinder sizes as part of routine maintenance or after activation.

Q: Where can Novec 1230 systems be installed - are they flexible in terms of mounting and space?

A: Yes, the system supports ceiling and wall mounting, with modular or centralized arrangements to suit varied architectural layouts. This allows protection of spaces up to 800 m3 depending on system design.

Q: What are the environmental benefits of using Novec 1230?

A: Novec 1230 agent features zero ozone depletion potential and a global warming potential of less than 1, making it an eco-friendly choice for fire suppression with minimal long-term environmental impact.

Q: How does Novec 1230 ensure safety for people present during discharge?

A: Novec 1230 is non-toxic and safe for use in occupied spaces, as per ISO 14520 and NFPA 2001 standards. The silent discharge and electrically non-conductive nature further ensure safety for both occupants and electronics.

Q: What is the process for integrating Novec 1230 with existing fire alarm or detection systems?

A: Novec 1230 systems are compatible with smoke and heat detectors as well as addressable fire alarm panels, enabling straightforward integration for both new projects and retrofit upgrades.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Electrical Panel fire suppression system Category

Co2 Fire Suppression system

Co2 Fire Suppression system

Price 100000.0 INR / Set

Minimum Order Quantity : 1 Set

Max Flow Rate : 1.6kg/sec

Control Type : auto

Fire Class : c

Mounting Type : floor

Fire Suppression System CO2 Gas

Fire Suppression System CO2 Gas

Price 80000.0 INR / Set

Minimum Order Quantity : 1 Piece

Max Flow Rate : 7kg/sec

Control Type : Mechanical valve

Fire Class : A,B and C

Mounting Type : Floor/ wall



Back to top