Novec-1230 Based Fire trace system

Novec-1230 Based Fire trace system
Novec-1230 Based Fire trace system

Novec-1230 Based Fire trace system Specification

  • Product Type
  • Fire Trace System - Novec-1230 Gas
  • Color
  • white
  • Usage
  • Industrial
  • Material
  • Mild steel
  • Application
  • Fire Trace System for electrical panels
 

Novec-1230 Based Fire trace system Trade Information

  • Minimum Order Quantity
  • 1 Set
  • Supply Ability
  • 500 Sets Per Month
  • Delivery Time
  • 4 Week
  • Main Domestic Market
  • All India, South India, Central India, West India, North India, East India, Gujarat, Karnataka, Kerala, Lakshadweep, Mizoram, Meghalaya, Manipur, Andhra Pradesh, Bihar, Chandigarh, Daman and Diu, Goa, Jharkhand, Odisha, Punjab, Assam, Delhi, Dadra and Nagar Haveli, Andaman and Nicobar Islands, Arunachal Pradesh, Maharashtra, Nagaland, Rajasthan, Sikkim, Tamil Nadu, Telangana, Tripura, Pondicherry, Uttar Pradesh, Uttarakhand, West Bengal, Chhattisgarh, Haryana, Himachal Pradesh, Jammu and Kashmir, Madhya Pradesh
  • Certifications
  • ul/ ce/ fm/ lpcb
 

About Novec-1230 Based Fire trace system

An electrical panel gas flooding system is a fire suppression system used to protect electrical panels or switchgear from the risk of fire. Electrical panels and switchgear are critical components in electrical systems, and if a fault occurssuch as a short circuit or overheatingthese components can catch fire. A gas flooding system is designed to suppress or extinguish fires quickly to prevent damage and reduce the risk of further electrical hazards.

Key Features and Functionality:

  1. Gas Agent: The system uses a specific type of gas (often inert gases like FM-200, Novec 1230, or CO2) to suppress the fire. These gases are non-conductive, meaning they can be used in electrical environments without causing additional harm to equipment.

  2. Detection System: Smoke or heat detectors within the electrical panel or the surrounding area detect abnormal conditions. When a fire is detected, the system triggers the release of the gas agent.

  3. Activation: When the fire is detected, the gas is quickly released into the electrical panel or compartment, flooding the area and reducing the oxygen level to a point where the fire can no longer sustain itself.

  4. Advantages:

    • Speed: Gas-based systems work rapidly to extinguish fires, minimizing damage.

    • Non-Damaging: The gas does not leave any residue, unlike traditional water-based sprinkler systems.

    • Safety: These systems are designed to be safe for personnel in the area, though proper ventilation may be required, especially for CO2 systems.

  5. Types of Gas Suppression Systems:

    • FM-200: A clean agent gas, commonly used because its effective at extinguishing fires while being safe for electronic equipment and humans.

    • Novec 1230: Another clean agent with a very low global warming potential (GWP), safe for sensitive equipment.

    • CO2: While effective in fire suppression, CO2 can be hazardous to people in high concentrations, so careful design to protect human life is critical.

  6. Maintenance: Regular testing and maintenance are necessary to ensure that the system will activate correctly in the event of a fire.

Applications:

  • Data Centers: Protects electrical equipment and servers that are crucial for operations.

  • Electrical Rooms: Used in commercial or industrial buildings where large electrical panels and equipment are present.

  • Power Plants: Where there are large amounts of electrical equipment at risk of overheating or failure.

Considerations:

  • Human Safety: Systems using gases like CO2 can displace oxygen, so any system using this agent needs to be equipped with safety measures such as alarms or ventilation to ensure people are evacuated before activation.

  • Design Compliance: Fire suppression systems should be designed in compliance with local fire safety codes and standards like NFPA (National Fire Protection Association) standards or UL (Underwriters Laboratories) guidelines.

This system is crucial for preventing large-scale electrical fires and ensuring the safety of both equipment and personnel. If you're working on designing or upgrading an electrical panel gas flooding system, consulting with a fire protection expert or an engineer would be a good idea to meet the required safety standards and optimize its efficiency.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire suppression system Category

Commercial Kitchen Fire Suppression System

Commercial Kitchen Fire Suppression System

Price 70000.0 INR / Set

Minimum Order Quantity : 1 Set

Alarm : YES

Application : commercial kitchen hood fire protection system

Product Type : fire suppression system

Usage : fire suppression system

Novec 1230 Suppression Fire Systems

Novec 1230 Suppression Fire Systems

Price 65000.00 INR / Set

Minimum Order Quantity : 1 Set

Alarm : YES

Application : Electrical Panel

Product Type : Novec 1230 Suppression system

Usage : fire suppression system

Electrical Panel Fire Suppression System

Electrical Panel Fire Suppression System

Price 75000.00 INR / Set

Minimum Order Quantity : 1 Set

Alarm : YES

Application : FIRE suppression system for electrical panels

Product Type : Novec 1230 Suppression system

Usage : fire suppression system

Suppression System

Suppression System

Price 55000 INR / Set

Minimum Order Quantity : 2 Sets

Alarm : YES

Application : ELECTRICAL ENCLOSURE FIRE FIGHTING

Product Type : FIRE SUPPRESSION

Usage : fire protection



Back to top