Indirect High Pressure CO2 Fire Suppression System is an automatic Carbon Dioxide Fire Suppression System designed to protect suitable electrical panels, machinery, generator rooms, compressor rooms, substations, switchgear rooms and other high fire risk enclosed equipment or areas. The system uses a dedicated fire detection arrangement to activate the release mechanism, while high pressure CO2 gas is discharged through separate piping and strategically positioned suppression nozzles.
In an Indirect High Pressure IHP CO2 Fire Suppression System, the detection element and discharge arrangement operate independently. Heat detection tubing, Linear Heat Sensing LHS cable, smoke detectors or other suitable detection technology can identify the fire condition and initiate the release sequence. The stored CO2 is then released through the discharge network to suppress the identified fire hazard.
Application Areas: Electrical Panel, MCC Panel, PCC Panel, HT Panel, LT Panel, MV Panel, VCB Panel, Switchgear Room, Electrical Room, Control Room, Relay Room, Substation Room, Transformer Area, Generator Room, DG Room, Compressor Room, Engine Room, Industrial Machinery, Process Equipment, Cable Gallery, Cable Room and other suitable enclosed hazards.
Equipment Protection: MCC Panels, PCC Panels, HT Panels, LT Panels, VCB Panels, Switchgear, Electrical Cabinets, Control Panels, Generators, Diesel Engines, Compressors, Industrial Machines, Pumps, Motors, Hydraulic Equipment, Process Machinery and other identified fire risk equipment as applicable to the engineered system.
Main Components: High Pressure CO2 Cylinders, CO2 Release Valves, IHP Release Arrangement, Heat Detection Tube or LHS Cable, Smoke or Heat Detectors where applicable, High Pressure CO2 Piping, CO2 Discharge Nozzles, Pressure Switch, Manual Release Station, Releasing Control Panel where applicable, Alarm Hooter, Strobe Light, Time Delay Unit, Warning Devices and Interface Modules.
Working Principle: The detection system continuously monitors the protected hazard. When the specified heat, smoke or fire condition occurs, the detection system activates the release mechanism. The high pressure CO2 agent is then discharged through dedicated piping and nozzles positioned to provide the required protection to the identified hazard.
IHP System Configuration: In an Indirect High Pressure CO2 System, the detection tubing or sensing system is primarily used for automatic detection and release initiation, while the extinguishing agent travels through an independent discharge piping network. This allows the nozzles to be strategically positioned around the protected equipment.
Key Features: Automatic Fire Detection, High Pressure CO2 Fire Suppression, Indirect Release Technology, Rapid CO2 Discharge, Dedicated Nozzle Protection, Automatic and Manual Release, Fire Alarm Integration, Equipment Shutdown Interface and Application Specific System Design.
Suitable Applications: Electrical Panel Fire Suppression, Switchgear Fire Protection, Generator Fire Suppression, Compressor Fire Suppression, Transformer Fire Protection, Industrial Machinery Fire Suppression, Control Room Fire Protection, Substation Fire Protection and Process Equipment Fire Suppression.
The required CO2 quantity, cylinder capacity, number of cylinders, discharge piping, nozzle quantity, nozzle size, nozzle locations and discharge time should be determined through an engineered design based on the protected volume, hazard geometry, ventilation, enclosure characteristics, fire risk and applicable system requirements.
For engineered CO2 installations, NFPA 12 may be considered as a design reference where applicable, together with project specifications, manufacturer requirements and local statutory fire safety requirements.
Important Safety: CO2 can create an oxygen-deficient atmosphere and can be hazardous or fatal to personnel. IHP CO2 systems require appropriate pre-discharge alarms, warning devices, time delay, evacuation procedures, release controls, ventilation shutdown and safety interlocks wherever personnel exposure is possible.
Fire Engineering Technology provides Indirect High Pressure CO2 Fire Suppression Systems, IHP CO2 Fire Suppression Systems, High Pressure CO2 Flooding Systems, Electrical CO2 Fire Suppression Systems, Industrial CO2 Fire Protection Systems and Automatic CO2 Fire Fighting Systems with design, engineering, supply, installation, testing, commissioning, maintenance, AMC and refilling services across India.
High Search Keywords: Indirect High Pressure CO2 Fire Suppression System, IHP CO2 Fire Suppression System, IHP CO2 System, Indirect High Pressure CO2 System, High Pressure CO2 Fire Suppression, High Pressure CO2 Flooding System, CO2 Fire Suppression System, CO2 Fire Fighting System, Automatic CO2 Fire Suppression System, CO2 Total Flooding System, CO2 Fire Extinguishing System, IHP CO2 Electrical Panel Fire Suppression, MCC Panel CO2 Fire Suppression, PCC Panel CO2 Fire Suppression, HT Panel CO2 Fire Suppression, LT Panel CO2 Fire Suppression, VCB Panel CO2 Fire Suppression, Switchgear Room CO2 Fire Suppression, Generator Room CO2 Fire Suppression, DG Room CO2 Fire Suppression, Compressor Room CO2 Fire Suppression, Transformer CO2 Fire Suppression, Industrial Machinery CO2 Fire Protection, Substation CO2 Fire Suppression, Automatic IHP CO2 Fire Fighting System, CO2 Flooding System Manufacturer India, IHP CO2 Fire Suppression Supplier India.




Price:
Price 35000.00 INR / Piece
Minimum Order Quantity : 1 Piece
Application : Electrical Panels, LT Panels, HT Panels, MCC Panels, PCC Panels, VCB Panels, DB Panels, PLC Panels, Control Panels, Electrical Cabinets, Switchboards, Switchgear Panels, Relay Panels, UPS Cabinets, Battery Cabinets, Automation Panels, Instrumentation Panels and Control Cabinets, Electrical Panel Fire, Cable Fire, Short Circuit Fire, Overheating Fire, Electrical Component Fire, Control Panel Fire, Switchgear Fire, Transformer Auxiliary Equipment Fire and Other Suitable Electrical Fire Hazards
Technology : DLP/ILP/IHP/DHP
Control Type : DLP/ILP/IHP/DHP
Fire Extinguisher Type : Automatic suppression system
Price 100000.00 INR / Piece
Minimum Order Quantity : 1 Piece
Application : Generator Room, DG Room, Transformer Room, Control Room, Electrical Room, Switchgear Room, MCC Room, Power Plant, Substation, Compressor Room, Industrial Machinery, Process Equipment, Turbine Area, Engine Room and Special Hazard Areas, Power Plants, Electrical Substations, Steel Plants, Cement Plants, Oil and Gas, Petrochemical, Chemical Industries, Manufacturing Plants, Automotive Industries, Mining, Process Industries, Engineering Industries and Industrial Facilities.
Technology : IHP/DHP/TFS
Control Type : Mechanical and electrical
Fire Extinguisher Type : Carbon Dioxide (CO2)
Price 40000.00 INR / Piece
Minimum Order Quantity : 1 Piece
Application : LV Panel, MCC Panel, Control Panel, DG Panel, HT Panel, HT Switchgear Panel, Indoor VCB Panel, Outdoor Electrical Panel, Feeder Panel, Incoming Panel, Outgoing Panel, Protection Panel, Relay Panel and Electrical Control Panel, VCB Panel Fire, Electrical Panel Fire, Cable Fire, Insulation Fire, Overheating Related Fire, Electrical Component Fire, Control Panel Fire, Switchgear Fire and Other Suitable Electrical Fire Hazards
Technology : Novec 1230
Control Type : Automatic
Fire Extinguisher Type : Electrical fire suppression system
Price 45000.00 INR / Piece
Minimum Order Quantity : 1 Piece
Application : MCC Panel, PCC Panel, HT Panel, LT Panel, MV Panel, VCB Panel, RMU Panel, PLC Cabinet, APFC Panel, DB Panel, Control Panel, Relay Cabinet, Switchgear Cabinet, Electrical Enclosure, Automation Cabinet, UPS Cabinet, Battery Cabinet, Inverter Cabinet, Telecom Cabinet, Server Cabinet, Network Cabinet, CNC Machine, EDM Machine, Generator, DG Set, Compressor, Hydraulic Unit, Industrial Machinery, Paint Equipment and Process Equipment, Electrical Panels, Electrical Cabinets, Switchgear, Control Electronics, PLC Systems, UPS Equipment, Power Electronics, Server Equipment, Telecom Equipment, Industrial Machines, Generator Equipment and other enclosed electrical or electronic assets
Technology : Tube Based Active Fire Suppression
Control Type : Automatic
Fire Extinguisher Type : Clean agent or ABC type (commonly used, not specified on image)