Fire Trace Indirect Release System
Fire Trace Indirect Release System

Fire Trace Indirect Release System

Price 70000 INR/ Piece

MOQ : 1 Piece

Fire Trace Indirect Release System Specification

  • Operating Pressure
  • 16 bar
  • Shape
  • Cylinder
  • Technology
  • Indirect Release, Clean Agent System
  • Fire Extinguisher Type
  • Clean Agent Fire Suppression
  • Features
  • Early fire detection, Quick release
  • Connectivity Type
  • Local (mechanical)
  • Working Temperature
  • 110C detection
  • Control Type
  • Automatic, Mechanical
  • Installation Type
  • Inside enclosure
  • Mounting Type
  • Enclosure mounted
  • Application
  • CNC machine, Panel protection, Diesel genset, Server rack, Bus engine
  • Capacity
  • 9 kg
  • Pressure
  • 16 bar
  • Actuation
  • Non-electric release
  • Refilling Option
  • Available
  • Detection Temperature
  • 110C
  • Alert Panel
  • Indicator light included
  • Application Coverage
  • Panel/machine/engine
  • System Type
  • Indirect release
  • Cylinder Material
  • Steel body
  • Tube Length
  • 25 m
  • Discharge Method
  • Valve controlled
  • Color
  • Red
  • Agent Type
  • Clean agent
  • Maintenance
  • Low maintenance
  • Physical Size
  • Compact design
 

Fire Trace Indirect Release System Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 10 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About Fire Trace Indirect Release System



Explore the monumental efficiency of the Fire Trace Indirect Release System, a trending choice for unmatchable fire suppression. Designed with potent clean agent technology, this compact, steel-bodied system features a 25-meter detection tube and non-electric actuation for swift, automatic response. Select this solution for coverage of CNC machines, server racks, bus engines, and more. Early fire detection, quick release, and indicator-light alerts ensure safety at 16 bar with low maintenance. Its refillable, enclosure-mounted cylinder fits seamlessly for robust panel and engine protection across India.

Advanced Application and Potent Commercial Usages

Select the Fire Trace Indirect Release System for robust protection inside enclosures such as CNC machines, server racks, diesel gensets, and bus engines. Its indirect application method enables early detection and targeted, valve-controlled suppression with a clean agent. Monumental benefits include a non-electric, automatic actuation, compact design, and indicator-light alert panel. This system is trending among commercial users, offering local mechanical connectivity and low maintenance for manufacturers, suppliers, and facility managers.


Sample Policy, Export Market, and Supply Ability

We are pleased to provide samples for assessment, with shipment arranged upon request at a competitive asking price. Our main export markets encompass India and international clients seeking the lowest price and exceptional value. With a steady supply ability ensured by a network of dealers, distributors, manufacturers, and wholesalers, we guarantee prompt delivery and support to fabricators and service providers seeking potent fire safety solutions.


FAQ's of Fire Trace Indirect Release System:


Q: How does the Fire Trace Indirect Release System operate?

A: The system uses a 25-meter detection tube filled with a potent clean agent that detects heat at 110C. On sensing fire, it automatically triggers valve-controlled discharge without the need for electric power, delivering rapid suppression.

Q: What is the primary benefit of using a clean agent in this system?

A: The clean agent is non-conductive and leaves no residue, making it ideal for protecting sensitive electronics and machinery without causing collateral damage.

Q: Where can the Fire Trace Indirect Release System be installed?

A: This compact, enclosure-mounted system is designed for installation in CNC machines, server racks, control panels, diesel gensets, and bus engines, offering flexible protection in diverse industrial and commercial settings.

Q: When should maintenance be performed on the system?

A: The Fire Trace Indirect Release System requires only periodic maintenance due to its robust, low-maintenance design. Inspection schedules depend on application intensity, but general checks are recommended at least annually.

Q: What is the process for refilling the cylinder after discharge?

A: After a discharge event, the steel cylinder can be conveniently refilled by an authorized service provider or distributor, ensuring the system is quickly restored to unmatchable operational readiness.

Q: How does the alert panel function during a fire event?

A: An integrated indicator light on the alert panel notifies users of a release, ensuring prompt awareness and appropriate response if manual intervention is needed.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Trace Suppression System Category

Fire Trace System - Tube Based Fire Suppression System

Fire Trace System - Tube Based Fire Suppression System

Price 35000 INR / Piece

Minimum Order Quantity : 1 Piece

Mounting Type : Wall/cabinet mounted

Application : Server Room, UPS Room, LV Panel, MCC Panel, Transformer Room, Battery Room, Control Panel

Fire Extinguisher Type : Clean agent suppression

Capacity : 125 Kg

Fire Trace DLP Suppression System

Fire Trace DLP Suppression System

Price 65550 INR / Piece

Minimum Order Quantity : 1 Piece

Mounting Type : Wall Mount

Application : Transformer Room, LV Panel, MCC Panel, Electrical Room, DG Panel, Battery Room, Server Room, Data Center, UPS Room, Control Panel

Fire Extinguisher Type : Clean agent

Capacity : 2.5/5.0/10.0 Lbs

Novec1230 Tube fire suppression system

Novec1230 Tube fire suppression system

Price 50000 INR / Piece

Minimum Order Quantity : 1 Piece

Mounting Type : Vertical

Application : Electrical Panel, Industrial Plant, Data Center, Control Room, Archive Room, Server Room, Medical Facility, Electrical Room, Transformer Room

Fire Extinguisher Type : Tube fire suppression system

Capacity : 2.5 lbs to 21 lbs

FK 5112 Gas Suppression System

FK 5112 Gas Suppression System

Price 35000 INR / Piece

Minimum Order Quantity : 1 Piece

Mounting Type : Wall mounted cabinet

Application : Industrial Machinery, CNC Machine, Server Room / Data Center, Vehicle Engine Bay, Electrical Panel

Fire Extinguisher Type : Clean agent