Direct Low Pressure fire suppression Specification

  • Coating Type
  • crome
  • Usage
  • FIRE SUPPRESSION
  • Operating Pressure
  • 15-18 Bar
  • Mounting Type
  • wall/ panel side
  • Fire Extinguisher Type
  • dlp cylinder
  • Energy Efficiency Rating
  • 5 star
  • Dimension (L*W*H)
  • 1x1x1 Meter (m)
  • Control Type
  • mechanical
  • Product Type
  • DLP fire suppression
  • Input Power
  • Volt (V)
  • Warranty
  • 5 YEARS
  • Alarm
  • yes
  • Features
  • direct low pressure
  • Weight
  • 1-9 Kilograms (kg)
  • Temperature Range
  • 100-120 Celsius (oC)
  • Connectivity Type
  • standard
  • Technology
  • DLP system
  • Fire Class
  • A,B,C
  • Working Temperature
  • 100-120 Celsius (oC)
  • Coverage Area
  • entire area Square Meter (m2)
  • Frequency
  • 50 Hertz (HZ)
  • Installation Type
  • customize
  • Voltage
  • Volt (v)
  • Material
  • UL listed
  • Shape
  • fire cylinder
  • Color
  • red
  • Application
  • FIRE SUPPRESSION - DLP system
  • Max Flow Rate
  • as per NFPA
  • Capacity
  • 1-9 Kg
  • Diameter
  • 4/6 Millimeter (mm)
  • Pressure
  • 195 PSI
 

Direct Low Pressure fire suppression Trade Information

  • Minimum Order Quantity
  • 1 Set
  • Payment Terms
  • Others
  • Supply Ability
  • 500 Sets Per Month
  • Delivery Time
  • 4 Week
  • Sample Available
  • No
  • Packaging Details
  • STANDARD
  • Main Domestic Market
  • All India
  • Certifications
  • ISI
 

About Direct Low Pressure fire suppression

Direct Low Pressure (DLP) Fire Suppression System  

Direct Low Pressure Fire Suppression System (DLP) is a compact automatic fire detection and suppression solution designed to extinguish fire directly at the point of origin inside electrical panels, server racks, CNC machines, battery cabinets, UPS systems, control panels, switchgear, and enclosed equipment. The system uses low-pressure stored clean agent or gas and a heat-sensitive polymer detection tube that acts as both detector and discharge line.


When exposed to abnormal heat or flame, the detection tube ruptures at the fire location, allowing the extinguishing agentsuch as Novec 1230 (FK-5-1-12), FM-200 (HFC-227ea), or COto discharge directly onto the fire, ensuring ultra-fast suppression without water, residue, or damage to sensitive electronics.


Key Features

  • Direct Low Pressure (DLP) automatic fire suppression

  • Tube-based detection & direct discharge system

  • No external power, control panel, or detectors required

  • Clean agent / CO options available

  • Non-conductive & residue-free suppression

  • Compact design with easy installation & low maintenance


Applications

  • Electrical Panels & Switchgear

  • Server Racks & IT Cabinets

  • CNC Machines & Industrial Enclosures

  • Battery Cabinets & UPS Systems

  • Control Panels & Automation Equipment


Standards & Compliance

  • Designed in line with NFPA 2001 Clean Agent Fire Suppression Systems

  • ISO 14520 compliant (for clean agents)

  • Suitable for localized electrical & electronic fire protection


Trending & High-Search Keywords 

Direct low pressure fire suppression system, DLP fire suppression system, tube based fire suppression system, automatic fire suppression system, electrical panel fire suppression, server rack fire protection, clean agent fire suppression, localized fire suppression system.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire protection system Category

Direct Fire Suppression System

Direct Fire Suppression System

Price 50000.0 INR / Set

Minimum Order Quantity : 1 Set

Weight : 19 Kilograms (kg)

Temperature Range : 100120 Celsius (oC)

Warranty : 12 MONTHS

Application : FIRE FIGHTING Direct low pressure system

Automatic Fire Detection And Suppression System For Mining Vehicles

Automatic Fire Detection And Suppression System For Mining Vehicles

Price 90000.0 INR / Set

Minimum Order Quantity : 1 Set

Weight : 20 Kilograms (kg)

Temperature Range : 150180 Celsius (oC)

Warranty : 12 months

Application : FIRE FIGHTING AFDSS

Indirect Low Pressure systems

Indirect Low Pressure systems

Price 35000.0 INR / Piece

Minimum Order Quantity : 1 Set

Weight : 1535 Kilograms (kg)

Temperature Range : 150180 Celsius (oC)

Warranty : 12 months

Application : FIRE FIGHTING ILP Suppression

Firetrace Tube and gas Based Fire Extinguishing System

Firetrace Tube and gas Based Fire Extinguishing System

Price 70000.0 INR / Set

Minimum Order Quantity : 1 Piece

Weight : 1525 Kilograms (kg)

Temperature Range : 100120 Celsius (oC)

Warranty : 12 months

Application : FIRE FIGHTING Fire trace tube suppression system



Back to top